WebCTRL® for Facility Administrators

Course Overview

If you have experience with the Automated Logic WebCTRL system but you’re responsible for making effective decisions for the care and operation of your facilities WebCTRL for Facility Administrators is for you. In this course, you will get refreshed by work with the WebCTRL user interface, create operators and privileges, develop schedules, troubleshoot with alarms and trends, and document using WebCTRL’s reporting features. This course covers more advanced features and scenarios associated with the WebCTRL system. Troubleshooting is a focus with an emphasis on deciphering logic pages and using add-on features to enhance the user’s experience. Upon successful completion of this course, the student will be able to configure and deploy complex features, such as advanced alarming and custom trending. They will also learn to set up location-dependent security privileges, as well as operators and privileges within groups.

keyboard_arrow_right View the Schedule

Course Objectives

After successfully completing this course, you will be able to use Automated Logic’s WebCTRL interface to quickly and efficiently:

  • Navigate WebCTRL 
  • Setup Users and Privileges 
  • Create Schedules 
  • Enable Trends 
  • Configure Alarms and Actions 
  • Manage Reports 
  • System Settings 
  • Manual Commands 
  • Advanced security 
  • Advanced trending 
  • Advanced alarming 
  • Advanced reporting 
  • Factory supported Add-Ons 
  • Read Logic

Prerequisites

None.

Course Formats

Traditional Classroom

A live instructor will lead up to 12 students (course dependent) in hands-on exercises with minimal lecture in between. Using the situated learning techniques of the Kirkpatrick Model, this methodology fosters a collaborative learning environment

Instructor-Led eLearning

A live instructor will lead students using video conferencing and remote access software. The student will have remote access to a training station to complete hands-on tasks, giving them a virtual classroom experience from many miles away. This course is hosted in the same 2-day timeframe and manner as the traditional classroom format.

Video-Led Virtual

The video-led virtual training allows the student to take up to 9 business days to complete the equivalent of a 1-3-day, instructor-led course. Using video tutorials as the instructor, students will execute the workbook tasks and upload assignments using the Automated Logic Training Portal, asking questions through the discussion board where a dedicated instructor will facilitate. This format also offers “instructor hours” where students have live contact with a certified instructor and other registered students.

Course Outline

Navigation

  • WebCTRL system architecture
  • Architecture – floorplan exercise
  • Use a room sensor

Operator Access

  • Privileges overview
  • Create an operator for yourself
  • Create operators and assign privileges

Schedules

  • Review the school year calendar
  • Create WebCTRL schedule groups
  • Create WebCTRL schedules
  • Edit and delete schedules
  • Check your work
  • Run schedule reports

Trends

  • Create a trend graph
  • Copy a trend graph
  • Enabling trending for a point
  • Using time lapse

Alarms

  • Alarm Notification Client
  • Create and Verify an alarm action
  • Manage an alarm incident (Alarm Popup)
  • Alarm Page Overview – View Tab 
  • Create a Custom Alarm Category 
  • Enable Standard Alarm Points 
  • Global Copy Alarm Parameters 
  • Alarm Source Reports 
  • Custom Alarm Messages (Point Level) 
  • Custom Alarm Messages (Equipment Level) 
  • Custom Alarm Messages (Network Level) 
  • Area Level Alarm Actions (Write to File) 
  • System Level Alarm Actions (Send Email or SMS) 
  • Other Alarm Reports & Functions

Global Modify

  • View or change a single property in multiple programs

Reports

  • Schedule a report

Logic

  • Verify a sequence of operation
  • Edit logic parameters
  • Jump To feature (Logic Page Review) 
  • Jump To feature (Tracing a value from a graphics page) 
  • Jump To feature (Tracing a value from reports) 
  • FDD Overview / Tuning 
  • FDD Overview / Reports 
  • Study a Sequence of Operations 
  • Reverse Engineer (AHU System) 
  • Reverse Engineer (Boiler System) 
  • Reverse Engineer (Chiller/Tower System) 
  • Sketch the communication path 
  • Source Tree Functionality in WebCTRL

WebCTRL Reporting

  • Custom Report Enhancements (Categories & Logos*) 
  • Customize an Equipment Summary Report 
  • Report Manager (Report Templates) 
  • Legacy Reports (For troubleshooting your system) 
  • Scheduling Reports (Advanced and Legacy)

Other Advanced WebCTRL Features

  • E-signatures*
  • Manual Commands (WebCTRL Interface) 
  • Autopilot v2.0 (Installing and Using) 
  • Autopilot v2.0 (Operators and Privileges)

Advanced Security*

  • Location-dependent Security 
  • Operator Accounts with multiple access 
  • Security Assignments Report 
  • Recording reasons for edits 
  • Location and System Audit Logs

*Optional WebCTRL Package required

Class Requirements

To receive a certificate for this course student must be present for the entire course, complete all workshops and receive a grade of 70% on graded final.

Traditional Classroom

A live instructor will lead up to 12 students (course dependent) in hands-on exercises with minimal lecture in between. Using the situated learning techniques of the Kirkpatrick Model, this methodology fosters a collaborative learning environment

Instructor-Led eLearning

A live instructor will lead students using video conferencing and remote access software. The student will have remote access to a training station to complete hands-on tasks, giving them a virtual classroom experience from many miles away. This course is hosted in the same 2-day timeframe and manner as the traditional classroom format.

Video-Led Virtual

The video-led virtual training allows the student to take up to 9 business days to complete the equivalent of a 1-3-day, instructor-led course. Using video tutorials as the instructor, students will execute the workbook tasks and upload assignments using the Automated Logic Training Portal, asking questions through the discussion board where a dedicated instructor will facilitate. This format also offers “instructor hours” where students have live contact with a certified instructor and other registered students.

Navigation

  • WebCTRL system architecture
  • Architecture – floorplan exercise
  • Use a room sensor

Operator Access

  • Privileges overview
  • Create an operator for yourself
  • Create operators and assign privileges

Schedules

  • Review the school year calendar
  • Create WebCTRL schedule groups
  • Create WebCTRL schedules
  • Edit and delete schedules
  • Check your work
  • Run schedule reports

Trends

  • Create a trend graph
  • Copy a trend graph
  • Enabling trending for a point
  • Using time lapse

Alarms

  • Alarm Notification Client
  • Create and Verify an alarm action
  • Manage an alarm incident (Alarm Popup)
  • Alarm Page Overview – View Tab 
  • Create a Custom Alarm Category 
  • Enable Standard Alarm Points 
  • Global Copy Alarm Parameters 
  • Alarm Source Reports 
  • Custom Alarm Messages (Point Level) 
  • Custom Alarm Messages (Equipment Level) 
  • Custom Alarm Messages (Network Level) 
  • Area Level Alarm Actions (Write to File) 
  • System Level Alarm Actions (Send Email or SMS) 
  • Other Alarm Reports & Functions

Global Modify

  • View or change a single property in multiple programs

Reports

  • Schedule a report

Logic

  • Verify a sequence of operation
  • Edit logic parameters
  • Jump To feature (Logic Page Review) 
  • Jump To feature (Tracing a value from a graphics page) 
  • Jump To feature (Tracing a value from reports) 
  • FDD Overview / Tuning 
  • FDD Overview / Reports 
  • Study a Sequence of Operations 
  • Reverse Engineer (AHU System) 
  • Reverse Engineer (Boiler System) 
  • Reverse Engineer (Chiller/Tower System) 
  • Sketch the communication path 
  • Source Tree Functionality in WebCTRL

WebCTRL Reporting

  • Custom Report Enhancements (Categories & Logos*) 
  • Customize an Equipment Summary Report 
  • Report Manager (Report Templates) 
  • Legacy Reports (For troubleshooting your system) 
  • Scheduling Reports (Advanced and Legacy)

Other Advanced WebCTRL Features

  • E-signatures*
  • Manual Commands (WebCTRL Interface) 
  • Autopilot v2.0 (Installing and Using) 
  • Autopilot v2.0 (Operators and Privileges)

Advanced Security*

  • Location-dependent Security 
  • Operator Accounts with multiple access 
  • Security Assignments Report 
  • Recording reasons for edits 
  • Location and System Audit Logs

*Optional WebCTRL Package required

To receive a certificate for this course student must be present for the entire course, complete all workshops and receive a grade of 70% on graded final.